Fujitsu Error Code 42, Indoor Coil Sensor Fault

Clipped to the copper tubes inside your indoor unit sits a small sensor that quietly prevents some big problems.

It stops the coil turning into a block of ice in summer and stops cold air blasting into the room on winter mornings. Fujitsu error code 42 tells you the board has lost a trustworthy reading from that sensor. This guide explains its role, the usual causes of the fault and how a technician fixes it.

What does Fujitsu error code 42 mean?

Fujitsu service information generally lists code 42 as an indoor heat exchanger temperature sensor error. The heat exchanger is the indoor coil, the finned block of copper tubes and aluminium that cools or warms the air. A thermistor attached to the coil reports its temperature to the indoor board.

When the reading falls outside the expected range, the board decides the sensor circuit has failed, usually because of an open or short circuit. It then stops the system and displays code 42, or the matching light pattern on models without a numeric display.

Why the coil sensor matters

Preventing ice in cooling mode

In cooling, the indoor coil runs cold so it can absorb heat and moisture from the room. If it gets too cold, moisture freezes on the fins, airflow drops and ice builds quickly. The coil sensor watches for this and tells the system to ease off before freezing begins.

Stopping cold drafts in heating mode

In heating, the indoor fan waits until the coil has warmed up before blowing air into the room. Without that delay, the first minutes of heating would push cold air at you. The coil sensor tells the board when the coil is warm enough to start the fan.

Guarding against overheating

During heating, the sensor also helps protect against the coil getting too hot, which could happen if airflow drops because of a clogged filter or a slow fan.

Supporting defrost decisions

On many models, the indoor coil reading also feeds into the logic the system uses to manage outdoor defrost cycles and refrigerant flow.

Common causes of code 42

Sensor slipped off the coil

The sensor sits in a small clip or pocket on the coil. Vibration, servicing or cleaning can loosen it. A sensor hanging in the air may still read a temperature, though usually not one the board expects, and over time the loose wire can be damaged.

Moisture damage

The coil is the wettest place in the indoor unit during cooling. Water can work its way into a sensor with damaged sealing, changing its resistance or causing it to fail entirely.

Broken or chafed wire

The sensor wire runs along the coil and through the unit to the board. Sharp fin edges, metal brackets and repeated flexing can wear through the insulation.

Corroded plug

Humid conditions, especially in coastal homes, can corrode the plug where the sensor connects to the board.

Board input fault

Less often, the circuit on the indoor board that reads the sensor fails.

Signs that sometimes appear before the code

A failing coil sensor may cause odd behaviour before triggering code 42.

  • Ice forming on the indoor coil even with clean filters.
  • Water dripping from the indoor unit after ice melts.
  • A long delay before warm air arrives in heating mode.
  • Cold air blowing at the start of heating.
  • The indoor fan stopping and starting during heating.

Our pages on a Fujitsu air conditioner freezing up and not heating cover these symptoms from other angles.

Safe checks you can do

  1. Switch the system off and isolate the power.
  2. Open the front panel and check the filters.
  3. Clean the filters and let them dry completely.
  4. Look for ice on the coil. If present, leave the system off until it melts.
  5. Refit the filters and close the panel.
  6. Restore power and test the system.

Our guide on how to clean Fujitsu air conditioner filters explains the safe steps.

Do not chip ice or touch the coil

Coil fins are thin and bend easily, and the sensor wire runs close by. Never chip at ice or push anything into the coil. Let ice thaw naturally with the system off.

How a technician diagnoses code 42

Locating the sensor

The technician removes the front cover and finds the coil sensor, checking that it sits firmly in its clip or pocket.

Measuring resistance

They unplug the sensor and measure its resistance, comparing the result with the expected value for the coil temperature at that moment, using the service information for your model.

Inspecting the wiring

They follow the wire from the coil to the board, looking for chafing, cuts or corrosion.

Testing the board

If the sensor and wire test fine, they confirm whether the board reads a known good sensor correctly.

How the coil and the sensor work together through a summer day

Picture a hot, humid Sydney afternoon. You switch on cooling, and the compressor ramps up. Within minutes, the indoor coil drops well below room temperature, and the coil sensor reports each change to the board. As the coil cools, water from the air condenses on the fins and drips into the drain pan.

Now imagine the filter has collected a lot of dust. Less air flows across the coil, so it keeps getting colder. A healthy sensor notices the temperature approaching freezing and tells the board to slow the compressor or pause cooling briefly. Once the coil warms slightly, cooling resumes. You might never notice this happening.

With a faulty sensor, that protection fails. The coil may keep dropping until ice forms. Ice blocks airflow further, more ice forms and eventually water spills when everything melts. In other cases, the sensor reading looks so wrong that the board stops the system and displays code 42 straight away.

Winter mornings and warm start

Heating brings a different challenge. When you switch on heating on a cold morning, the indoor coil starts cold. If the indoor fan ran immediately, it would blow chilly air across the room. Instead, the board waits for the coil sensor to report a comfortable temperature before starting the fan, a feature often described as warm start or cold draft prevention.

When the sensor misreads, that delay can become too short, too long or erratic. You might feel a cold blast at start up, wait an unusually long time for warm air or notice the fan stopping and starting. These symptoms do not always mean a sensor fault, since normal defrost cycles also pause heating, yet they are worth mentioning if they appear alongside the code.

Water, mould and sensor life

The indoor coil spends much of summer wet. That moisture, combined with dust, creates a friendly environment for mould and slime. Over time, this growth can coat the sensor and its clip, holding moisture against the seal. Eventually water may reach the sensing element, shifting its readings or causing failure.

Keeping the coil clean through regular servicing reduces this risk. Running the fan for a short while after cooling, where your model allows, helps dry the coil and limits growth. Our page on a Fujitsu air conditioner smell explains how moisture inside the unit leads to odours as well.

Testing beyond the sensor

Even when a sensor tests faulty, a careful technician asks why it failed. For example, a sensor that slipped because of a broken clip needs a new clip as well. Similarly, water that reached the sensor through a repeatedly blocked drain means the drain needs attention. Likewise, a wire that chafed on a sharp edge needs better routing. Fixing these underlying issues prevents the new sensor from failing for the same reason.

Multi head systems and coil sensors

On multi head systems, each indoor unit carries its own coil sensor. The outdoor unit relies on readings from all of them to balance refrigerant flow between rooms. A faulty coil sensor in one room can therefore affect how that room cools or heats, and sometimes how the whole system behaves. If only one indoor unit shows code 42, the problem almost certainly sits in that unit. Note which room shows the code when booking, since it lets the technician go straight to the right place.

A note on cleaning products

Foaming coil cleaners and household sprays sold for air conditioners might seem like an easy fix for a dirty coil. However, they can leave residue, damage sensor seals and corrode delicate parts if misused. They also tend to push dirt deeper into the coil and drain. Professional cleaning with suitable methods is gentler on the sensor and more effective overall.

Details worth noting before the visit

Before the technician arrives at your home, try to note when code 42 first appeared and whether it shows in cooling, heating or both. Record any ice, drips or cold drafts you noticed, plus how long ago the system was last serviced. If the code appears only on humid days or only during the first minutes of heating, mention that pattern, as it often points toward moisture or a loose sensor.

Typical repairs

  • Refitting a sensor that has slipped from its clip.
  • Replacing a damaged sensor clip or pocket.
  • Repairing a chafed or broken wire.
  • Cleaning or replacing a corroded plug.
  • Replacing the coil sensor.
  • Replacing the indoor board in the rare case its input has failed.

Room sensor versus coil sensor

Fujitsu indoor units usually carry at least two sensors. The room sensor, covered on our error code 41 page, measures air returning to the unit and decides how hard the system works. The coil sensor measures the coil itself and protects against freezing, overheating and cold drafts. Both use similar thermistors, yet they sit in very different places and fail for slightly different reasons. The coil sensor faces far more moisture, which makes water damage a bigger factor.

Why a sensor fix should include a clean

Many coil sensor problems happen alongside a dirty coil. Dust and grime trap moisture against the sensor and fins, which encourages corrosion and mould. When a technician replaces or refits a coil sensor, cleaning the coil at the same time often makes sense. It improves airflow, reduces the chance of freezing and helps the new sensor last. Our service page explains what a full clean involves.

Cassettes and ducted units

On cassettes and ducted units, the coil sensor sits deeper inside the unit, often behind panels in the ceiling or roof space. Access takes longer, and ducted fan coils may require working in the roof. Mention your system type when booking so the technician can plan the visit.

Keeping the coil sensor healthy

  • Clean filters regularly so the coil stays clear.
  • Book periodic servicing to keep the coil and drain clean.
  • Avoid spraying products into the indoor unit that could damage sensor seals.
  • Act quickly on ice or water drips rather than letting them repeat.

Fujitsu error code 42, getting it fixed

If cleaning filters and restarting does not clear Fujitsu error code 42, the coil sensor circuit needs testing. When booking, mention whether you have seen ice, water drips or cold air in heating mode, and whether anyone recently cleaned inside the unit.

Call 02 9071 1142 or use our booking page to arrange a visit. A technician will check the sensor, wiring and board, then restore the quiet protection that keeps your coil from freezing in summer and your heating comfortable through winter.

Frequently asked questions

What does Fujitsu error code 42 mean?

It generally points to a fault with the indoor coil temperature sensor, also called the heat exchanger sensor.

What does the coil sensor do?

It helps prevent freezing in cooling, stops cold drafts in heating and guards against overheating.

Can a slipped sensor cause code 42?

Yes. A sensor that has come loose from the coil can give false readings and its wire can be damaged.

Why did I see ice before the code?

A faulty coil sensor may fail to stop the coil getting too cold, allowing ice to form.

Is code 42 the same as code 41?

No. Code 41 relates to the room sensor, while code 42 relates to the indoor coil sensor.

Should the coil be cleaned during the repair?

Often yes. A clean coil improves airflow and helps the sensor last.

{“@context”:”https://schema.org”,”@type”:”HVACBusiness”,”@id”:”https://fujitsu.sydneyaircare.com.au/#business”,”name”:”Sydney Air Care, Fujitsu Service”,”url”:”https://fujitsu.sydneyaircare.com.au/”,”description”:”Fujitsu air conditioner repair, service and troubleshooting across Sydney. Independent service provider, not affiliated with Fujitsu.”,”areaServed”:[{“@type”:”City”,”name”:”Sydney”},{“@type”:”State”,”name”:”New South Wales”}],”parentOrganization”:{“@type”:”Organization”,”name”:”Sydney Air Care”,”url”:”https://sydneyaircare.com.au/”},”telephone”:”+61 2 9071 1142″} {“@context”:”https://schema.org”,”@type”:”FAQPage”,”mainEntity”:[{“@type”:”Question”,”name”:”What does Fujitsu error code 42 mean?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”It generally points to a fault with the indoor coil temperature sensor, also called the heat exchanger sensor.”}},{“@type”:”Question”,”name”:”What does the coil sensor do?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”It helps prevent freezing in cooling, stops cold drafts in heating and guards against overheating.”}},{“@type”:”Question”,”name”:”Can a slipped sensor cause code 42?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Yes. A sensor that has come loose from the coil can give false readings and its wire can be damaged.”}},{“@type”:”Question”,”name”:”Why did I see ice before the code?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”A faulty coil sensor may fail to stop the coil getting too cold, allowing ice to form.”}},{“@type”:”Question”,”name”:”Is code 42 the same as code 41?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”No. Code 41 relates to the room sensor, while code 42 relates to the indoor coil sensor.”}},{“@type”:”Question”,”name”:”Should the coil be cleaned during the repair?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Often yes. A clean coil improves airflow and helps the sensor last.”}}]}